Cooperative Extension Service

Management of Alternative On-Site Wastewater Systems - A Case Study

North Gloucester Pilot On-Site Systems
Treatment Systems Performance

ParametersRSFISFBio- FilterBioclereRTF*
** Colburn St. Langsford St. Washington St. Bittersweet Rd. High St. Vale Ct. Brierwood St.
Total-N...................IN
(mg/l)...................OUT
...........................% Rem.
95.6
60.8
36
153.3
78.6
49
76.2
61.3
20
78.1
55.9
28
39.3
26.8
32
78.4
29.2
63
32.1
22.1
71
Total-P....................IN
(mg/l)...................OUT
..........................% Rem.
8.7
3.0
66
16.7
5.1
69
11.4
8.3
27
7.8
8.4
N.A.
7.5
6.4
15
10.0
4.8
52
6.5
4.5
53
MGAS.....................IN
(mg/l)...................OUT ..........................% Rem.
18.1
0.3
98
23.1
2.1
9.1
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
6.4
0.5
92
15.2
1.1
93
N.A.
N.A.
N.A.
F. Colif....................IN 323,582 938,627 211,584 99,628 155,452 1,489,019 70,399

Coin./100ml).....OUT
..........................% Rem.
10,285
97
7,189
99
5,182
98
1,377
99
7,407
95
121,943
92
23,018
67


RSF = Recirculating Sand Filter
ISF = Intermttent Sand Filter
Bio-Filter = Waterloo Bio-Filter
IN = Septic Tank Effluent (except for Brierwood Site).
OUT = Treated Effluent (Before Leachfield, Except for Brierwood Site).
Bioclere = AWT Bioclere
RTF = ORENCO Trickling Filter
*RTF is installed in the septic tank and discharges to a sand- lined bed;
Samples are collected at the tank outlet & at the bottom of the bed.