Water Considerations for Container
Production of Plants
HIL #557 Revised 7/99
Doug Bailey, Ted Bilderback, and Dick Bir,
Extension Horticulture Specialists
Department of Horticultural Science
North Carolina State University
Water quality and quantity issues are extremely important in
container production of plants. The following article addresses both
quality and quantity issues for greenhouse and nursery production
from a best management practices view.
Surface water basins are the primary source of irrigation at most container nurseries. Wells are often used to recharge (dilute / freshen) and resupply water in basins. Many nurseries have always captured and recycled irrigation runoff to have adequate irrigation supplies. As environmental concern about runoff has increased in recent years this practice has increased. Growers can reduce potential problems caused by nutrients, pesticide residues and disease organisms which may be present in recycled water by allowing return water to filter through grass strips, and other vegetated areas such as a secondary impoundment or constructed wetlands before allowing the water to reenter primary irrigation supplies. Aerators will help oxygenate surface waters and enhance microflora breakdown of water impurities. Many nurseries have also begun water treatment procedures such as chlorination and extensive filtration before reapplying water.
Most nursery crops grown in 1 to 5 gallon containers are irrigated with overhead impact sprinklers. A single sprinkler nozzle may require up to 15 gallons per hour for proper performance. Professionals who design irrigation systems for container nurseries suggest a minimum of one acre-inch (approximately 27,000 gallons) of water storage per acre of nursery stock per day be used in planning water supplies. Another common recommendation used for planning water supply is an estimated annual use of 5 to 10 acre-feet of irrigation water per acre of nursery stock. If container stock were irrigated for 163 days in a year at the rate of 1 acre-inch, approximately 4.5 million gallons per acre would be required annually. This is equivalent to 13 acre-feet of water per acre of nursery stock. Therefore, we recommend using 13 acre-feet of water per acre of nursery stock per year when estimating water needs.
Greenhouses also use large volumes of water for irrigation, estimated to be two quarts per square foot of covered area per day. A one-acre greenhouse uses approximately 22,000 gallons of water per day for irrigation purposes. This does not include water for evaporative cooling systems.
Water used for evaporative cooling during the summer months can dramatically increase the total water use. Under "optimum" evaporative conditions, greenhouse pad and fan cooling system water use can be as much as 0.045 gallons per 1,000 cubic feet per minute (cfm) of fan capacity. This equates to a peak demand of roughly 19 gallons per minute (gpm) for an acre of greenhouse. Keep in mind that evaporative rates vary drastically with temperature and relative humidity conditions. Taking into account relative humidity and temperature variances throughout the day and season, a more realistic "average" cooling water requirement would be 11 gpm for an acre of greenhouse. If pad and fan cooling is used 12 hours per day, cooling water would be about 8,000 gallons per acre per day.
An estimate of the water supply available from an irrigation basin can be made by:
If we apply 1/2 inch of water per acre of nursery stock on a daily basis, we can divide the storage capacity by 13,500 gallons to determine the number of irrigation days available from the basin. This calculation doesn't take into account evaporation and all other losses of water from the basin, but is useful for planning irrigation supply.
In practice, most growers apply water to an area of containers for a specific time, such as 1 hour. The actual volume of water applied to an area is highly variable. It is dependent on:
A commonly recommended volume for 1 gallon containers (7.5 inch top diameter) is 1 pint of water (0.125 gallons) with each irrigation. If 27,000 gallons of water (1 acre inch) is applied over an acre of 1 gallon container nursery stock, 0.19 gallons will enter the pot (plant canopy interference not considered). Actual volumes of irrigation applied can be determined if the nurseryman installs a water meter in the main irrigation line after the pump.
Actual measurement of the water applied is the best method of determining uniformity of irrigation. Pots with taped holes, cans or cups can be placed throughout a block of nursery stock before an irrigation cycle and collected water measured after the cycle is over. Water volume applied per container can be approximated by placing collectors with the same diameter as the containers throughout the block and catching irrigation. If the volume collected is highly variable, inspect equipment such as risers and nozzle orifices. Make sure risers are perpendicular to the ground. If nozzle orifices appear irregular in shape or larger than new orifice openings, replace them. If wind creates water distribution problems, consider creating a windbreak.
Irrigation efficiency can also be determined by removing plants from containers and observing the degree of uniform wetness in the container watered. If the irrigation was adequate, there should be no dry spots in the container root zone and water should have moved through the entire container. If irrigation continues after water has begun draining from containers, fertilizers will be leached and runoff water will have elevated levels of nutrients.
Most growers irrigate until the driest plants are watered
adequately. If water is applied uniformly, less irrigation is
required. Increasing efficiency is the best way to conserve
water.
Your irrigation water should be tested periodically to determine its quality. It may contain essential nutrients such as iron at high enough concentrations to justify a reduction in the levels applied in the fertilization program. Waters may also contain harmful elements or biological organisms which require corrective procedures. Table 1 lists some of the more important quality factors to consider for irrigation water for greenhouse and nursery crop use. If test results indicate levels above the recommended upper limit for a particular factor, it does not necessarily mean the water source is unacceptable, rather that some water treatment or change in production fertilization may be required.
|
Table 1. Recommended upper limits of nutrients and chemical capacity factors for water used for greenhouse crops and for containerized nursery crops. Use of water exceeding these suggested limits may lead to nutritional problems in sensitive crops and / or require some form of water treatment or adjustment in crop fertilization programs. |
||
|---|---|---|
|
Capacity factor |
Upper limit for greenhouse use |
Upper limit for nursery use |
|
Substrate pH Factors |
||
|
pHA |
5.4 to 7.0 is acceptable |
5.4 to 7.0 is acceptable |
|
AlkalinityB
|
2 meq/L 100 ppm |
2 meq/L 100 ppm |
|
Salinity Factors |
||
|
Electrical conductivity (EC)
|
0.75 mmho/cm |
---- |
|
Total Dissolved SaltsD (TDS)
|
480 ppm |
---- |
|
Sodium absorption ratio (SAR) |
4 |
10 |
|
Sodium (Na) |
69 ppm (3 meq/L) |
69 ppm (3 meq/L) |
|
Chloride (Cl-) |
71 ppm (2 meq/L) |
71 ppm (2 meq/L) |
|
Macro Elements |
||
|
Total NitrogenE (N)
|
10 ppm (0.72 meq/L) 44 ppm (0.72 meq/L)
|
10 ppm (0.72 meq/L) 44 ppm (0.72 meq/L)
|
|
PhosphorusF (P)
|
1 ppm (0.03 meq/L) 3 ppm (0.03 meq/L) |
1 ppm (0.03 meq/L) 3 ppm (0.03 meq/L) |
|
PotassiumF (K) |
10 ppm (0.26 meq/L) |
10 ppm (0.26 meq/L) |
|
CalciumG (Ca) |
0 to 120 ppm (0 to 6 meq/L) is normal range |
0 to 120 ppm (0 to 6 meq/L) is normal range |
|
MagnesiumG (Mg) |
0 to 24 ppm (0 to 2 meq/L)is normal range |
0 to 24 ppm (0 to 2 meq/L)is normal range |
|
Sulfur (S)
|
20 to 30 ppm (0.63 to 0.94 meq/L) 60 to 90 ppm (1.26 to 1.88 meq/L) |
20 to 30 ppm (0.63 to 0.94 meq/L) 60 to 90 ppm (1.26 to 1.88 meq/L) |
|
Micro Elements |
||
|
Aluminum (Al) |
0 to 5.0 ppm is normal range |
0 to 5.0 ppm is normal range |
|
Boron (B) |
0.5 ppm |
0.5 ppm |
|
Copper (Cu) |
0.2 ppm |
0.2 ppm |
|
FluorideH (F-) |
1.0 ppm |
1.0 ppm |
|
IronI (Fe) |
0.2 to 4.0 ppm |
0.2 to 4.0 ppm |
|
Manganese (Mn) |
1.0 ppm |
1.0 ppm |
|
Molybdenum |
---- |
---- |
|
Zinc (Zn) |
0.3 ppm |
0.3 ppm |
|
Organisms to Test For |
||
|
Iron fixing bacteria |
||
|
Plant pathogens |
||
|
AWater
with high pH should be analyzed for alkalinity and can be
safely used if alkalinity can be neutralized. |
||
Substrate pH Factors. High water pH and high alkalinity can be limiting factors in container production of greenhouse and nursery crops. An understanding of both is needed to accurately treat water with a high pH.
A pH reading is a measurement of the hydrogen ion concentration of a solution (how acidic or basic a solution is), and readings range from 0 (most acidic) to 14 (most basic). Nutrient availability and future plant growth can be affected severely by high substrate and irrigation water pH (Table 2; Figure 1). Although pH 7 is considered "neutral" (not acidic or alkaline), 7 is not the optimum pH for irrigation waters or substrate solutions for nutrient availability and growth in container production due to the substrate components typically used in greenhouse and nursery production.
|
Table 2. Effects of substrate pH on nutrient uptake in plants. |
|
|---|---|
|
Low pH leads to: |
High pH leads to: |
|
Increased uptake of:
|
Increased uptake of: molybdenum |
|
Decreased uptake of:
|
Decreased uptake of: iron |

The recommended range of irrigation water pH and substrate solution pH for container production depends on the crop being grown. The generally accepted pH range is 5.4 to 7.0 for irrigation water and 5.2 to 6.3 for the substrate solution. Acid treatment may be needed prior to use in container production, if water pH and alkalinity are too high.
Alkalinity is a measure of a water's capacity to neutralize acids. Bicarbonate ions (HCO3- ) from dissolved salts such as calcium bicarbonate (Ca(HCO3)2), sodium bicarbonate (NaHCO3), and magnesium bicarbonate (Mg(HCO3)2); and carbonate ions (CO3- - ) from dissolved salts such as calcium carbonate (CaCO3) are the major chemicals contributing to alkalinity in irrigation water. Hydroxide ions (OH- ) are but a minor contributor in most cases. Ammonia, borates, organic bases, phosphates, and silicates can also be minor contributors to alkalinity.
Since bicarbonates and carbonates are the major components of water alkalinity, most laboratories assume that Total Carbonates (TC = carbonates + bicarbonates) equals alkalinity. In most cases, this is a safe assumption. For most waters in North Carolina, bicarbonates account for more than 90% of all alkalinity present.
The term "alkalinity" should not be confused with the term "alkaline," which describes situations where pH levels exceed 7.0. Laboratory test results sometimes express alkalinity as a calcium carbonate equivalent, using milligrams per liter (or parts per million) of calcium carbonate (mg/L or ppm CaCO3). The term "total carbonates" (TC) may also be used by some labs to refer to alkalinity of a solution. The Agronomic Divison Laboratory of NCDA reports alkalinity as meq/L TC. Some laboratories assume that all alkalinity is derived solely from bicarbonates (HCO3- ) and will report bicarbonates as mg/L or meq/L. To convert between these two units, use the following values: 1 meq/L HCO3- = 61 mg/L HCO3-.
Alkalinity establishes the buffering capacity of water and affects how much acid is required to change the pH. The following example may help explain the importance of alkalinity when trying to acidify water (Figure 2): Grower A has a water with a pH of 9.3 and an alkalinity of 87 mg/L HCO3- (TC = 1.42 meq/L). To reduce the pH of this water to 5.8, it takes 15.8 fl oz. of 35% sulfuric acid per 1,000 gallons of water. In contrast, Grower B has a water with a pH of 8.3 and an alkalinity of 378 mg/L HCO3- (TC = 6.20 meq/L). To reduce this water to a pH of 5.8, it takes 68.6 fl oz. of 35% sulfuric acid per 1,000 gallons of water. Despite the fact that Grower B's water is a full pH unit lower than Grower A's, it takes more than four times more acid to lower the pH to 5.8. Both alkalinity and pH are important to consider when adjusting the pH of a water.
Figure 2. Titrations of two different waters with sulfuric acid. Notice that although the beginning pH of Grower A water is a full unit higher than Grower B water, it takes more than 4 times the acid (68.6 fl oz compared to 15.8 fl oz for Grower A water) to drop Grower B water to pH 5.8, due to the greater alkalinity in Grower B water.
Alkalinity can be a major problem in North Carolina, especially in the coastal plain region. Levels below 2 meq/L and lower are safe for most crops. However, plug seedlings are more sensitive to alkalinity because the small volume of substrate provides little buffering against a rise in pH. Problems can occur in plug production if using water with more than 1.5 meq/L. If the alkalinity of your irrigation water is above 2.0 meq/L (or above 1.5 meq/L for a plug producer), you should consider injecting an acid to neutralize the bicarbonates (alkalinity) present to prevent an undesirable rise of substrate pH over time.
Consideration of alkalinity naturally leads to Hardness. Hardness is not alkalinity! Hardness refers to the amount of calcium and magnesium in water, generally expressed as if it were all calcium and if all of it were the compound calcium carbonate (CaCO3). Hardness can be expressed as mg/L or ppm of calcium carbonate.
High concentrations ("hard water") of calcium and magnesium in the water will generally be accompanied by similarly high levels of bicarbonate and a high alkalinity. That is why water hardness is sometimes used as an indirect indicator of water alkalinity. As previously mentioned, bicarbonates will cause a rise in substrate solution pH over time. Thus, it is wise to use less limestone in the substrate when high hardness water is encountered. The calcium and magnesium bicarbonates you are adding with the water are equivalent to "liquid limestone."
It is possible to have hard water without high alkalinity. An example would be water that is high in calcium and / or magnesium chloride. In this example, the problem associated with hard water is not a potential rise in pH, rather a potentially toxic level of chloride.
The take home message on water hardness is: if you have hard water, you need to look at:
Salinity Factors. Salinity is the total quantity of salts dissolved in water, and one way to measure salinity is by measure of a water's Electrical Conductivity or EC. A water's ability to conduct an electrical current is directly related to the concentration of dissolved salts -- pure water is a relatively poor conductor of electricity, whereas salty water is a good conductor. The greater the EC, the more dissolved salts are present in solution.
Although EC is an indicator of Total Dissolved Salts (TDS), it offers no information on what salts are present and no information on the concentrations of each salt; only the total conductivity of all salts present is measured. Since individual salts conduct electricity at different rates, it is difficult to accurately convert from an EC value to a milligrams per liter value of total dissolved salts (TDS) without knowing the actual concentration of each salt present. A commonly accepted conversion factor derived from the average of many water samples is: 1 mmho/cm EC = 640 ppm TDS.
The soluble salt level in irrigation water, often referred to as EC (electrical conductivity), should ideally be under 0.75 millimho per centimeter(mho x10-3/cm) for seedlings, less than 1.0 mmho/cm for other greenhouse crops, and less than 2.0 mmho/cm for other nursery crops. Younger seedlings tend to be more sensitive to high salt levels than other crops, so EC monitoring is especially important for a plug grower. When a high salt level builds up in the substrate it prevents water from entering the plant roots. This results in desiccation symptoms of wilting, stunting, and burning of leaf margins.
Many growers easily become confused with different units used to report soluble salts. For example, Table 1 uses millimhos (mmho) per cm (mho x10-3/cm ) as the standard units. Both the NCDA Agronomic Division Laboratories and the NCSU Plant Disease and Insect Clinic (PDIC) report soluble salts of solutions in mho x10-5 per cm. It is easy to convert between the two by adjusting the decimal point (e.g. 0.75 mmho/cm = 75 mho x10-5/cm), but you must pay attention to units used by different laboratories to prevent reading errors. Refer to Table 3 for more conversions.
|
Table 3. Conversions for conductivity meters and pens. |
||
|---|---|---|
|
Beckman Solubridge
|
||
|
Myron Meters
|
||
|
Conductivity Pens - Several ranges of conductivity can be purchased
|
||
|
Total Dissolved Salts (TDS) Pens
|
||
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
Another salinity factor beyond soluble salts is the Sodium concentration and the Sodium Absorption Ratio or SAR. Sodium is an essential element for some plants such as celery and spinach, but most greenhouse and nursery crops have minimal sodium requirements. The SAR is a calculated value that indicates the relative concentration of sodium to that of calcium and magnesium in a water. Irrigation with waters having an SAR above 4 can result in root absorption of toxic levels of sodium, but this problem can be prevented by the addition of calcium. Water containing greater than 3 meq/L sodium should not be used for overhead irrigation of ornamentals and greenhouse plants as foliar absorption of sodium can lead to sodium toxicity in sensitive species. Sodium toxicity, whether due to root absorption or foliar absorption of Na, is expressed as marginal leaf burn on older foliage.
The final salinity factor of concern is Chloride concentration. Though it not usually listed as an essential micronutrient, chlorine (as chloride) is needed in small quantities by plants. However, in excess, greater than 2 meq/L, chloride can become a production problem. The principal effect of too much chloride (Cl- ) is an increase is the osmotic pressure of the substrate solution that can reduce the availability of water to plants and lead to wilting. High chloride levels can also lead to toxicity symptoms in container production. When absorbed by plant roots, the chloride ion is transported to leaves, where it accumulates. Some species, such as roses, azaleas, camellias, and rhododendrons develop leaf edge burn, leaf necrosis, and leaf abscission when too much chloride is accumulated.
Macro Elements. The macro elements Nitrogen (N), Phosphorus (P), Potassium (K), Calcium (Ca), Magnesium (Mg), and Sulfur (S) are elements essential for plant growth, and at moderate levels will not cause production problems. However, content of these elements should be evaluated as an indicator of potential contamination of the water (for N, P, and K) as well as an indicator of fertilizer requirements (for Ca, Mg, and S).
For example, nitrogen levels greater than 10 ppm are rarely found in North Carolina waters. If your water contains greater than 10 ppm N, there is a strong possibility that the water has been contaminated with a fertilizer or other contaminant. If there is greater than 1 ppm of phosphorus and / or 10 ppm potassium, the water may be contaminated with fertilizer, detergent, or some other contaminant. Although these nutrient levels should not hinder plant growth, the possibility of contamination should be further investigated, and the water should not be used for human or livestock consumption if concentrations of N, P, and K exceed the upper limits listed in Table 1.
Calcium and magnesium are normally found in North Carolina waters in the ranges given in Table 1. It is acceptable to use water containing the highest levels of Ca and Mg listed, if you reduce the amount of calcium and magnesium supplied in the fertilizer program and if the ratio of calcium to magnesium in your water source is within acceptable limits.
What is an acceptable Ca : Mg ratio in an irrigation water? The calcium and magnesium ratio in the substrate solution (and in the irrigation water) should be 3 Ca to 1 Mg if expressed as meq/L or 5 Ca to 1 Mg if expressed as ppm Ca and Mg. There is a fairly wide latitude of variance around these ratios. However, if the ratio shifts a great deal from this, a deficiency of the nutrient which is undesirably low in the ratio will occur. The more common problem is a low level of magnesium relative to calcium. In this case it is necessary to supplement occasionally with a Mg source such as magnesium sulfate (Epsom salts). Examine the ratio of calcium to magnesium (Ca : Mg) in your water to anticipate whether the substrate Ca : Mg will tend to shift out of the desired range.
Sulfur concentrations in North Carolina waters are usually less than 25 ppm, and excessive sulfur is not a normal problem. Table 1 lists recommended levels of sulfur for best plant growth. Usually, growers must add additional sulfur to reach these recommended application rates.
Micro Elements. Waters can contain small concentrations of Aluminum (Al), Boron (B), Copper (Cu), Fluoride (F- ), Iron (Fe), Manganese (Mn), Molybdenum (Mo), and Zinc (Zn). With the exception of Al and F-, these elements are essential to plant growth and are required in small quantities.
Aluminum in irrigation water is rarely found in concentrations high enough to lead to toxicities, and should not be a major concern for most growers.
Among the specific plant micronutrients found in water, boron can be particularly troublesome. A concentration of 0.5 ppm (mg/L) is safe for any irrigation use. A level greater than 0.5 ppm is above the upper limit and could lead to toxicity symptoms in boron-sensitive crops. Boron toxicity can first show up as orange-brown necrosis along the margins of older leaves. Flecking can also occur on the underside of leaves.
Other micronutrients that can be excessive in irrigation water are iron, manganese, zinc, and copper. Check levels and assure that concentrations are below the levels listed in Table 1 prior to using water. Micronutrient toxicities are more probable when the pH of the substrate solution is low, rendering the micronutrients more available for plant uptake. If the water source does contain high concentrations of these micronutrients, adjustments in the fertilization program should be made to prevent an overabundance of the elements.
Fluoride is often added to municipal water at a concentration of 1 ppm to prevent tooth decay. This level is safe for most crops but not for members of the lily family such as the genera Chamaedorea, Chlorophytum, Ctenanthe, Dracaena, Marantha, Spathiphyllum and a few other plants. Toxic levels of fluoride causes scorch of the tips of older leaves.
Harmful Organisms. Iron Fixing Bacteria in irrigation water can lead to many problems, including a bluish sheen on plant surfaces and brown stains on plants. The blue and brown deposits are two separate water quality problems both related to high iron content in irrigation water applied by overhead irrigation systems. The bluish bronze sheen is due to iron bacteria. They occur naturally in the soil and can be a problem in well and basin irrigation sources. In wells they often gum submersible pumps and cause them to need replacement. On basins, the oily sheen over the surface of the water is due to iron bacteria. They keep the iron in the water from settling out so when irrigation goes over plants so does the bluish iron deposit. In propagation houses you also can see a slimy yellowish mass that plugs nozzles. That is the iron bacteria.
The red-brown deposit is iron. Well water containing iron can be pumped into basins and some of the iron will settle out, but if you have iron bacteria it confounds the problem. One very important item to check is the irrigation intake. Growers have avoided or reduced the problem of iron deposits by making sure that their irrigation intakes are 18 to 30 inches below the surface of the water. They need to be at least 18 inches deep to prevent vortexing from the surface. Intakes too close to the bottom pull settled iron sediment off the bottom. Checking the location of the intake is difficult, but it is worth the effort.
If raising or adjusting the intake is not the answer, then the next choices become more expensive. The first step is to have the water analyzed at a laboratory such as NCDA (Agronomic Division N.C. Soil Testing Lab 4300 Reedy Creek Road, Raleigh, N.C. 27607; Phone 919.733.2655). Most labs need at least 16 ounces of water, so a clean plastic drink bottle sample will be fine. Water analysis at the NCDA lab costs $4.00. Although less than 0.5 ppm iron in water can stain risers and coat plants, 0.5 to 3 ppm is common in irrigation water in N.C. A foliar sample from coated plants would also be good to see how much deposit is ending up on the plants.
Employ the following methods to control iron and iron bacteria deposits:
Bailey, D. and T. Bilderback. 1998. Alkalinity control for irrigation water used in nurseries and greenhouses. NC State University Hort. Info. Lflt. #558. (available at www2.ncsu.edu/floriculture/)Farnham, D.S., R.F. Hasek, and J.L. Paul. 1985. Water quality: its effects on ornamental plants. University of California Cooperative Extension Leaflet #2995.
Reed, D.M. (ed.). 1996. Water, media, and nutrition for greenhouse crops. Ball Publishing, Batavia, Ill.